TitleProduct

Hospital Infusion Pumps

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Jiangsu

  • Validity to:

    Long-term effective

  • Last update:

    2019-07-01 01:11

  • Browse the number:

    502

Send an inquiries
+
Suzhou Meditech Imp. & Exp. Co., Ltd
Contactaixin:

meditech(Mr.)  

Email:

telephone:

phone:

Arrea:

Jiangsu

Address:

Room B2-103, Building 6, No.2288, Wuzhong Avenue, Yuexi, Wuzhong District, Suzhou.China

Website:

http://www.vetmeditech.com/ http://meditech.shbroad.com/

+

Friendliness

● Compact design with light weight

● 3" large LCD screen allows infusion status to be viewed easily

● Embedded handle allows for easy transportation

● Straightforward IV set installation

● Intuitive programming procedure with quick guidance on screen


Safety

● High accuracy: ±5%, satisfying neonatal use

● Water-proof membrane on fingers preventing leakage into pump body


Infusion pump

● Anti-bolus, Drug name display, History record, Last therapy parameter memory

● IP34 dust and water protection


Connectivity

● Nurse call/ RS 232/ DC input



Specifications and functions

Dimension

146 x 193 x 95mm

Infusion set

Applicable to GB 8368-2005 disposals; diametersΦ3.5-4.5mm, thickness 0.8-1.2mm

Infusion mode

Rate mode, Time mode, Body weight mode, Sequential mode

Flow rate range

0.1~1500ml/h

Accumulated volume

0.1~9999 ml

VTBI

0.1~999.9 ml, increment is 0.1 ml; 1000-9999ml, increment is 1ml

Increment

0.1~999.9 ml/h, increment is 0.1 ml/h; 1000~1500 ml/h, increment is 1 ml/h

Accuracy

≤ ±5%

KVO rate

0.1-5.0 ml/h, adjustable, increment is 0.1ml/h

Bolus rate

0.10-1500ml/h

Purge rate

800ml/h

Occlusion

Low 150±125 mmHg (20kPa); Medium 525±125 mmHg (70kPa); High 900±180 mmHg (120 kPa)

Air bubble detection

Single bubble detection: 50, 100, 250, 500, 800l μl
Accumulated bubble detection: 0.1-4.0ml/h, adjustable

Screen

3.0" LCD monochrome screen, 240 x 128 pixels

Titration

Yes, increment is 0.1ml/h

Keypad lock

Yes

Pause

Yes

Self-test system

Yes

Last therapy parameter memory

Yes

Drug library

200 drugs

History record

1500 events

Weight

<1.6kg (not including clamp)

Handle

Embedded handle

Mounting type

Standard: Vertical Pole

Alarm Volume

1-8 levels selectable

Language

8, Chinese, English, Spanish, French, Russian, Turkish, Portuguese, German

Alarm


VTBI done, VTBI near done, KVO finish, Bottle empty, door open, IV set not installed, occlusion, air in line, drop error, system error, system abnormal, battery low, battery empty, reminder, AC power disconnection, standby end

Safety Requirement

AC power

100-240V (50/60Hz, 0.4-0.14A)

DC power

10-16V (2.25-1.5A)

Battery type

Lithium

Battery operation time

>4 hours@25ml/h

Charging time

≤6 hours@100%

Classification

CF, Class I

IP Grade

IP 34

Temperature

5~40ºC for operating, -20~60ºC for storage

Humidity

15~95% for operating, 10~95% for storage

Air pressure

57~106kPa for operating, 50~106kPa for storage

Interface

Data interface

Supported, RS232

Nurse Call

Supported

DC input

Supported



http://www.vetmeditech.com/